Confirm
  • 400V PQC Industrial Module
  • 400V PQC Industrial Module
  • 400V PQC Industrial Module
  • 400V PQC Industrial Module
  • 400V PQC Industrial Module
  • 400V PQC Industrial Module
400V PQC Industrial Module
400V PQC Industrial Module
400V PQC Industrial Module
400V PQC Industrial Module
400V PQC Industrial Module
400V PQC Industrial Module
+

400V PQC Industrial Module

Brand: Zhiyuan New Energy Description: The PQC is a flexible power converter. First, the PQC measures the reactive current and harmonic current generated by the load. Then, it generates new reactive and harmonic currents with the same magnitude but in opposite phases, thereby eliminating the vast majority of reactive and harmonic currents in the power supply network.

Product inquiry phone:

    400V PQC Industrial Module

    • Product Description
    • Features & Advantages
    • Technical Parameters
    • Related manuals
    • Figure on the right
    • Commodity name: 400V PQC Industrial Module
    • Commodity ID: 1362032839481774080
    • 类型: Industrial automation
    • 品牌: Capni

    Brand: Zhiyuan New Energy Description: The PQC is a flexible power converter. First, the PQC measures the reactive current and harmonic current generated by the load. Then, it generates new reactive and harmonic currents with the same magnitude but in opposite phases, thereby eliminating the vast majority of reactive and harmonic currents in the power supply network.

    1. Working Principle

    Industrial-grade comprehensive power quality compensator (abbreviated as PQC ) Employs modern power electronics technology and is based on high-speed DSP A new type of specialized equipment for power harmonic mitigation and reactive power compensation, developed using digital signal processing technology for devices.

    It consists of two main parts: a reference current computation circuit and a compensation current generation circuit. By using external current transformers, the harmonic components and reactive power content in the power grid are detected in real time, generating the reference current. The reference current computation circuit continuously monitors the current flowing in the line, converts the analog current signal into a digital signal, and then sends it to a high-speed digital signal processor ( DSP ) Process the signal to separate harmonics from the fundamental wave, and use pulse-width modulation ( PWM ) The signal form sends a drive pulse to the compensation current generation circuit, driving... IGBT or IPM Power module To control the inverter to generate harmonic currents and reactive currents that meet the required specifications.

     

                 Figure 1-1 PQC Working principle diagram

    2. Basic Components

    PQC The system mainly includes the main contactor. KM1 Precharge Contactor KM2 Precharge resistor R Filter inductor L Voltage-type PWM Rectifier bridge ( VSR ) and DC bus capacitance C Wait.

    The system diagram is shown in the figure. 1-2 As shown, the resistor R For the system’s precharge resistor, when... KM2 After closing, the bus capacitor voltage of the system charges slowly. K M1 Control the main circuit while simultaneously connecting the precharge resistor. R Short circuit; An inductor is a power-transfer interface component between power converters and power systems. On the one hand, it serves as an energy-storage element; on the other hand, it filters out high-frequency switching ripple currents. Voltage-type PWM The rectifier bridge is The power conversion component of the PQC, composed of insulated-gate bipolar transistors (IGBTs), employs space vector pulse width modulation (SVPWM) technology to drive the IGBTs and generate a compensation current waveform. The DC capacitor module stores the DC energy generated by the IGBT power conversion module.

    Figure 1-2: Schematic Diagram of the PQC System

     

    • It can collect data such as three-phase system voltage, current, active power, reactive power, power factor, harmonic content, and harmonic current output from the device, via... GPRS The module is uploaded to the database. Mobile download is supported. APP and web browsing, enabling real-time device monitoring, historical data download, and device startup. / Shutdown and other operations.
    Key words:
    • 电能质量综合补偿装置
    • 工业型无功补偿谐波治理装置
    • 工业型PQC
    • Design Concept 40 The product developed for application environments features a vertical structural design for active modules. This structural model adopts a large-capacity... IGBT Power devices—selecting the effective value for the device. 3 More than double the rated capacity, with ample safety margins to ensure long-term operation even under heavy load and significant impact. The module employs axial-flow fans for heat dissipation, offering large airflow, sufficient air pressure, and excellent cooling performance. The entire cabinet adopts a bottom-inlet, top-outlet airflow configuration: axial-flow fans are installed at the top of the cabinet to extract air, while dust-proof louvers are positioned at the bottom to allow fresh air intake. This design effectively isolates the internal components from the external environment, making it particularly well-suited for high-temperature industrial settings and harsh environments—especially those with high dust concentrations. Examples include powder plants, stone-processing facilities, tile factories, cement plants, and similar applications.

    Anti-high-voltage distortion

    • Applicable to 5%-25% Application of harmonic voltage distortion rate in industrial load distribution systems, with a subtle-level instantaneous response speed and a total response time of less than... 10ms

    Comprehensive compensation, safety and stability

    • Harmonic mitigation, inductive and capacitive reactive power compensation—freely select your compensation combination.
    • Automatic flow limiting operation and comprehensive fault protection features.

    Advanced control strategies and topological structure design

    • Adopt LCL Topological structure filtering, when used with output current, does not introduce high frequencies. IGBT Switching harmonic interference is suppressed, and resonance will not occur regardless of the impedance of the on-site power grid system.

    Self-diagnosis and self-startup function for faults

    • The device is equipped with a self-recovery function that allows it to resume operation automatically after a shutdown caused by factors unrelated to the device itself. Before initiating self-recovery, the device will perform an automatic diagnosis of both the external power grid and the device itself; only if the diagnosis is successful can the device restart automatically. If the issue lies with the external power grid, the device will no longer attempt to start up and will transmit a device failure alarm to the host computer, while simultaneously illuminating its own fault indicator light.

    Remote IoT monitoring function (optional)

    • It can collect data such as three-phase system voltage, current, active power, reactive power, power factor, harmonic content, and harmonic current output from the device, via... GPRS The module is uploaded to the database. Mobile download is supported. APP and web browsing, enabling real-time device monitoring, historical data download, and device startup. / Shutdown and other operations.
  • Input

    System voltage ( V )

    400V AC  

    System voltage range

    ± 10%

    Frequency (Hz)

    50/60 ±5%

    Output and Installation Method

    Rated current ( Four )

    Module

    Full container

     

    100Kvar

    100 kVAR, 200 kVAR, 300 kVAR, 400 kVAR

    Type

    Industrial-grade module

    Complete cabinet

    Incoming line method

    Upstream line

    Upstream line / Bottom incoming line / Busbar running through the cabinet top

    (The cable entry method for the enclosure must be specified in the contract.)

    Performance metrics

    Filter rate

    90% ( Within the ordered capacity range, and with harmonic content of the load exceeding the ordered capacity. 30%)

    Filtering range

    2 to 13 Subharmonics (if you need to address even-order harmonics, please specify when placing your order)

    Full response time

    10ms

    Instant response time

    100us

    Dynamic current

    1.2 Rated capacity output of the dual-filter, 1min

    Power factor setting compensation

    Be equipped with

    Inductive or capacitive compensation

    Optional

    Protection

    Overload protection

    Automatic rate limiting in 100% Rated output

    Other protections

    Overvoltage protection, undervoltage protection, overtemperature protection

    Operating mode

    Single-unit or parallel operation

    Okay.

    Display and Operation

    Display interface

    7 Inch touchscreen

    Display status

    Current, voltage, power, harmonic distortion rate, and more

    Operation

    Multiple operation mode options, remote or local.

    Communication ( RS485 Interface)

    Modbus-RTU It features a remote monitoring interface and a backend database, enabling users to conveniently monitor various operating parameters of the device from internet-connected terminals.

    Phase Sequence Adaptive

    Be equipped with

    Environmental conditions

    Protection level

    IP20 (Customizable)

    Operating ambient temperature

    -10 Celsius ~40 Celsius

    Storage / Transportation temperature

    -40 Celsius ~60 Celsius

    Work / Storage humidity

    Relative humidity 20~95% No condensation. / Relative humidity 10~95%

    Altitude

    1000m The following (derating required for higher altitudes)

Get a free product quote

Our staff will contact you within 24 hours (on business days). If you require additional services, please feel free to call our service hotline:0512-50132658

Provide consumers with more solutions.


Copyright © Beijing Capni Technology Co., Ltd.