Shunt reactor
- Product Description
- Features & Advantages
- Technical Parameters
- Related manuals
- Figure on the right
Shunt reactor
-
- Commodity name: Shunt reactor
- Commodity ID: 1362032616638402560
- 类型: Power distribution/switching
- 品牌: Capni
Brand: Zhiyuan New Energy Description: This series of harmonic-resistant reactors is primarily designed to complement 0.4kV system power capacitors, improving the power factor of power systems. They effectively suppress higher-order harmonics in the power grid, reduce overloads on capacitors caused by harmonics, and prevent harmonic amplification. These reactors play a crucial role in ensuring the safe operation of capacitors, enhancing the waveform of network voltage, improving power supply quality, and promoting the safe and economical operation of the power grid. They are suitable for reactive power compensation and harmonic filtering applications involving 3rd, 5th, 7th, 11th, and 13th harmonic loads.
1. Introduction
This series of harmonic-rejection reactors is primarily designed to be used with power capacitors in 0.4kV systems. They help improve the power factor of power systems, effectively suppress higher-order harmonics in the grid, reduce overloading of capacitors caused by harmonics, and prevent harmonic amplification. These reactors play a positive role in ensuring the safe operation of capacitors, improving the waveform of network voltage, enhancing power supply quality, and promoting the safe and economical operation of the power grid. They are suitable for reactive power compensation and harmonic filtering applications involving 3rd, 5th, 7th, 11th, and 13th harmonic loads.
2. Features
Reactance rates: 6%, 7%, 12%, 14%, and non-standard customizations
Temperature rise at low temperature: ≤ 70 K (at rated current at power frequency)
Low noise: ≤ 48 dB (@ power frequency, measured at 1 m from the product)
Insulation class: Class H (180℃)
Withstand Voltage: Apply 4 kV AC between phases and to ground for 1 minute; no breakdown or flashover shall occur.
Linearity: 1.8In; inductance value no less than 0.95 of the rated inductance.
Overtemperature protection: NC 125℃ temperature control.
Implementation standard: GB/T 1094.6-2011 "Reactors"; IEC60076-6 "Reactors"
-
Rated Voltage (V)
Multiple voltage levels available: 0.25 kV, 0.28 kV, 0.45 kV, 0.48 kV, 0.525 kV
Rated capacity (kvar)
Multiple capacities available: 5 kvar, 10 kvar, 20 kvar, 30 kvar, 40 kvar, 50 kvar, 60 kvar
Wiring method
Single-phase, three-phase, separate compensation
Type
Copper core, aluminum core
Insulation class
H-Class (1801)
Dielectric withstand voltage
4 kV to ground and between phases, duration 1 ms, no breakdown.
Noise
w48dB (test distance: 1 meter from the reactor)
Terms of Use
Indoor
Working environment temperature
-25%~+40℃ (Ensure good ventilation inside the cabinet)
Storage/Transportation Temperature
-40℃~60℃
Spacing distance
Horizontal direction < 6 cm, vertical direction < 12 cm
Reactance rate
6%, 7%, 13%, 14%, and custom
Altitude
Below 2000m (Please call to explain if exceeding the requirement)
According to the standard
GB/1094.6-2011